Deye · Three-phase String Inverter

Deye SUN 30/33/35/36K G04

Three-phase string inverter family from 30kW to 36kW, with 2 MPP trackers, 98.6% maximum efficiency and IP65 protection.

  • 30-36kW
  • 2 MPPTs
  • 98.6% max. efficiency
  • IP65
Deye SUN-30/33/35/36K-G04 three-phase string PV inverter
SUN-30 / 33 / 35 / 36K-G04

Available Models

Four verified output options

Values below are taken from the Deye SUN-30/33/35/36K-G04 datasheet.

Model Nominal AC power Recommended PV power MPPTs Max. efficiency Weight
SUN-30K-G0430,000W45,000W298.6%28.7kg
SUN-33K-G0433,000W49,500W298.6%28.7kg
SUN-35K-G0435,000W52,500W298.6%28.7kg
SUN-36K-G0436,000W54,000W298.6%28.7kg

Datasheet Features

Features

01

2 MPPT architecture

Two MPP trackers with 3+3 strings per tracker and 40A operating current per tracker.

02

98.6% maximum efficiency

Maximum efficiency is 98.6% and European efficiency is 98.1%. MPPT efficiency is above 99%.

03

Zero export and VSG

Zero-export application and VSG application are listed, with optional string monitoring.

04

Specified protection

Type II SPD is specified on DC and AC sides. Anti-PID is optional. Protection degree is IP65.

Product Family

Specifications

Deye SUN-30/33/35/36K-G04 three-phase string PV inverter front view

For preliminary product matching. Confirm the exact model and destination-market grid requirements before quotation.

Maximum DC voltage
1100V
Start voltage
250V
MPPT voltage range
200-1000V
PV strings per MPP tracker
3+3
Max. operating PV input current
40A + 40A
Nominal AC voltage
220V / 380V, 230V / 400V
AC grid connection
3L / N / PE
THDi
<3%
Protection degree
IP65
Cooling
Intelligent air cooling
Operating temperature
-25 C to +60 C, derating above 45 C
Dimensions (W / H / D)
330 / 572 / 206mm
Interfaces
RS485 / RS232 / WiFi / LAN

Application Fit

Three-phase commercial and industrial PV projects

The SUN-30/33/35/36K-G04 family is intended for C&I rooftops requiring 30-36kW nominal AC output.

Technical Source

Manufacturer datasheet

Deye SUN-30/33/35/36K-G04 datasheet. Specifications may change; confirm the exact model before order placement.

View Official Datasheet

Project Enquiry

Request model matching and a quotation

Please provide the target model or output power, grid voltage, PV string design, destination market and required quantity.